Filters
Question type

Study Flashcards

The definition for intermediate metal conduit (IMC) and rigid metal conduit (RMC) is ____.


A) listed by the UL
B) determined locally
C) essentially the same
D) explained in terms of differing diameters

E) A) and D)
F) B) and C)

Correct Answer

verifed

verified

Contact of dissimilar metals (except for the combination of aluminum and steel) should be avoided wherever possible to lessen the potential for ____.


A) galvanic action
B) inadvertent shorting
C) structural weakening
D) static charging

E) A) and D)
F) All of the above

Correct Answer

verifed

verified

A

PVC bends must be made so that the conduit remains undamaged and the internal diameter of the conduit is ____.


A) not reduced
B) reduced by no more than one third
C) reduced by no more than one half
D) reduced by no more than two thirds

E) A) and D)
F) None of the above

Correct Answer

verifed

verified

All cut ends of IMC and RMC must be ____.


A) anchored in a junction box
B) welded
C) color coded
D) reamed

E) None of the above
F) B) and C)

Correct Answer

verifed

verified

Underfloor raceway dead ends must be ____.


A) open
B) accessible
C) closed
D) non-accessible

E) None of the above
F) B) and D)

Correct Answer

verifed

verified

The equivalent of ____ is the maximum allowed between pull points.


A) one quarter bends (90° total)
B) two half bends (180° total)
C) three quarter bends (270° total)
D) four quarter bends (360° total)

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

Surface nonmetallic raceways and their fittings must be designed so that sections can be mechanically coupled together and installed without subjecting the wires to ____.


A) bending
B) abrasion
C) compression
D) tension

E) All of the above
F) A) and D)

Correct Answer

verifed

verified

A multiconductor cable, optical fiber cable, or flexible cords of two or more conductors is treated as ____ for percentage conduit fill area calculations.


A) two conductors
B) three conductors
C) a single conductor
D) a neutral node

E) A) and C)
F) B) and C)

Correct Answer

verifed

verified

C

Bends must be made so that the conduit or tubing remains undamaged with its internal diameter ____.


A) diminished by no more than a tenth
B) diminished by no more than half
C) diminished by no more than a third
D) basically undiminished

E) C) and D)
F) None of the above

Correct Answer

verifed

verified

Half-round and flat-top raceways not over 4 inches in width must be covered by ____ or more of concrete (or wood) .


A) .25 inches
B) .5 inches
C) .75 inches
D) one inch

E) B) and C)
F) C) and D)

Correct Answer

verifed

verified

Rigid metal conduit (RMC) is a threadable raceway of ____ designed for the physical protection and routing of conductors and cables.


A) an incompressible material
B) circular cross section
C) galvanized steel
D) various bending radii

E) B) and C)
F) B) and D)

Correct Answer

verifed

verified

Raceway fill calculations are a prerequisite in ____ needed for particular circuits.


A) circuit loads
B) material requirements
C) schematic requirements
D) determining the size of raceway

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

Liquidtight flexible metal conduit (LFMC) is a raceway of circular cross section having a(n) ____ over an inner flexible metal core.


A) outer liquidtight, nonmetallic, sunlight-resistant jacket
B) inflexible PVC coating
C) immersible (water tight) surface
D) sunlight-resistant, rigid, metallic outer jacket

E) C) and D)
F) A) and B)

Correct Answer

verifed

verified

Grounding conductors are required for circuits over ____ amperes.


A) 10
B) 20
C) 30
D) 40

E) B) and D)
F) C) and D)

Correct Answer

verifed

verified

Splices and taps are permitted within surface metal raceway having a removable cover that ____.


A) is accessible at another junction
B) contains a trap facility
C) contains a branch to a junction box
D) remains accessible once installed

E) All of the above
F) B) and D)

Correct Answer

verifed

verified

NEC identifies ____ types of rigid PVC conduit.


A) two
B) three
C) five
D) ten

E) B) and D)
F) A) and B)

Correct Answer

verifed

verified

Electric metal tubing (EMT) provides protection from ____.


A) all but severe physical damage
B) inadvertent grounding
C) water damage
D) lightening

E) A) and B)
F) None of the above

Correct Answer

verifed

verified

Wireways are ____ housing and protecting electric wires (and cables) .


A) conductors for signaling circuits between a motor
B) troughs with hinged or removable covers for
C) ceiling fixtures connecting to luminaires or
D) current carrying junction boxes

E) None of the above
F) B) and C)

Correct Answer

verifed

verified

B

A group of conductors that fit into one conduit may not fit into another type because the ____ of different types of conduit vary.


A) interfaces
B) spacing requirements
C) internal diameters
D) carrying capacity

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

Raceways installed within drop ceilings must ____.


A) be grounded internally to support wires
B) have adequate ventilation on all sides
C) have secure support provided by the support wires and associated fittings
D) be connected directly to a junction box

E) All of the above
F) A) and D)

Correct Answer

verifed

verified

Showing 1 - 20 of 26

Related Exams

Show Answer