Approximately _______% of the x-ray beam incident on the patient is transmitted through the patient without interaction to become part of the image-forming beam.


A) 90-99
B) 80-89
C) 20-29
D) 1

E) A) and D)
F) None of the above

Correct Answer

verifed

verified

The positive beam limiting device (PBL) assures that the x-ray beam is collimated to __________________.


A) the exact part size
B) 1 cm inside image receptor size
C) the image receptor size
D) 1 cm outside image receptor size

E) B) and C)
F) A) and D)

Correct Answer

verifed

verified

The x-ray interaction that contributes to the clear parts of the image is _____________.


A) coherent scatter
B) Compton interaction
C) photoelectric interaction
D) pair production

E) A) and D)
F) C) and D)

Correct Answer

verifed

verified

Which kVp selection would result in the most scattered x-rays in the image-forming beam?


A) 90 kVp
B) 75 kVp
C) 60 kVp
D) 50 kVp

E) B) and C)
F) A) and D)

Correct Answer

verifed

verified

How can you improve image contrast with a heavy patient without increasing patient dose?


A) Lower kVp and raise mAs.
B) Use tight collimation.
C) Raise kVp and lower mAs.
D) Do both A and B.

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

Decreasing the kVp will increase ___________.


A) patient dose
B) image noise
C) Compton scatter
D) optical density

E) A) and D)
F) A) and C)

Correct Answer

verifed

verified

The use of a compression device will increase __________.


A) film fog
B) patient dose
C) contrast
D) scatter

E) A) and C)
F) A) and B)

Correct Answer

verifed

verified

C

A fixed aperture diaphragm should leave a _____ cm unexposed border on the film.


A) 0.1
B) 0.5
C) 1
D) 2

E) None of the above
F) A) and B)

Correct Answer

verifed

verified

The most commonly used beam restricting device is the ____________.


A) extension cone
B) variable collimator
C) aperture diaphragm
D) compression device

E) C) and D)
F) B) and C)

Correct Answer

verifed

verified

Photoelectric interactions increase when ___________ is decreased.


A) mAs
B) patient thickness
C) filtration
D) kVp

E) None of the above
F) C) and D)

Correct Answer

verifed

verified

D

The x-rays that are transmitted through the patient without interaction contribute to ______________.


A) useful information
B) film fog
C) image noise
D) All of the above

E) B) and C)
F) A) and C)

Correct Answer

verifed

verified

Lowering kVp ________ patient dose and _________ image contrast.


A) lowers, decreases
B) increases, decreases
C) lowers, increases
D) increases, increases

E) C) and D)
F) B) and C)

Correct Answer

verifed

verified

Beam restriction with a(n) ____________ is only accurate at a fixed SID.


A) aperture diaphragm
B) cone
C) collimator
D) PBL device

E) B) and C)
F) B) and D)

Correct Answer

verifed

verified

Scatter radiation increases as ___________________ increases.


A) photoelectric absorption
B) field size
C) filtration
D) contrast

E) A) and C)
F) A) and B)

Correct Answer

verifed

verified

The three primary factors influencing the intensity of scatter in the image-forming beam are ___________________.


A) mAs, kVp, and collimation
B) mAs, filtration, and grids
C) kVp, field size, and patient thickness
D) filtration, patient thickness, and mAs

E) C) and D)
F) B) and D)

Correct Answer

verifed

verified

The use of __________ improves contrast and reduces patient dose.


A) collimation
B) high kVp
C) low kVp
D) less filtration

E) A) and D)
F) None of the above

Correct Answer

verifed

verified

Image-forming x-rays include those which have been _________________.


A) transmitted without interaction
B) scattered through Compton interaction
C) absorbed through photoelectric interaction
D) Both A and B

E) A) and D)
F) C) and D)

Correct Answer

verifed

verified

D

Federal regulations passed in _____ required that positive beam limiting devices be on all manufactured x-ray collimators.


A) 1954
B) 1974
C) 1994
D) 2000

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

Compton scatter contributes to _____________.


A) useful information
B) image noise
C) image contrast
D) All of the above

E) B) and C)
F) A) and D)

Correct Answer

verifed

verified

Contrast resolution is improved by _____________.


A) tight collimation
B) lowering kVp
C) patient compression
D) All of the above

E) A) and C)
F) A) and D)

Correct Answer

verifed

verified