The metal frame that a receptacle or switch is built around is called a(n) ____________________.

Correct Answer

verifed

verified

A __________ switch would be used to control two lights from one location.


A) double-pole
B) single-pole
C) three-way
D) four-way

E) A) and C)
F) A) and D)

Correct Answer

verifed

verified

A(n) __________ line surge is caused by inductive loads in a residence such as spark igniters on gas ranges and clothes dryers, electric motors, and computers.


A) impulse
B) grounding
C) shorting
D) ring wave

E) None of the above
F) A) and B)

Correct Answer

verifed

verified

To GFCI protect receptacles that are downstream from a GFCI receptacle, the wiring going to those receptacles is connected to the ____________________ terminals on a feed-through GFCI receptacle.

Correct Answer

verifed

verified

If a white conductor in a Romex cable is connected to a traveler terminal on a three-way switch, it does not have to be re-identified because it is not 'hot' all the time.

A) True
B) False

Correct Answer

verifed

verified

Which of the following conductors are permitted to be used for the push-in method of attaching conductors to a device?


A) 14 AWG solid copper
B) 14 AWG stranded copper
C) 14 AWG aluminum
D) 14 AWG copper-clad aluminum

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

When more than one grounded conductor enters a device box, a wiring practice to use so that only one conductor gets connected to the silver terminal screw is to use a(n) ____________________.

Correct Answer

verifed

verified

Explain the drawbacks of the push-in method of securing conductors to devices.

Correct Answer

verifed

verified

The conductor is held in place only by a thin strip of copper that can weaken, allowing the conductor to pull free. The conductors can also pull free when the device is being installed in the device box.

The preferred method for connecting a circuit conductor to a device is to form a __________ in the wire, put it under a terminal screw, and tighten the screw properly.


A) terminal loop
B) curve
C) circle
D) jug handle

E) B) and D)
F) B) and C)

Correct Answer

verifed

verified

In all areas specified in Section 210.52, all nonlocking type 125 volt, 15- and 20- amp receptacles must be tamper-resistant. (General Rule)

A) True
B) False

Correct Answer

verifed

verified

The proper NEMA designation for a 30 amp, 125/250 volt receptacle installed for an electric clothes dryer is __________.


A) 5-15R
B) 6-30R
C) 14-30R
D) 10-30R

E) A) and D)
F) B) and D)

Correct Answer

verifed

verified

Describe different strategies that electricians use to properly position a duplex receptacle into a device box.

Correct Answer

verifed

verified

Spacers are needed when the device box w...

View Answer

A grounding conductor may not be __________.


A) bare
B) green
C) green with yellow stripes
D) green with white stripes

E) A) and C)
F) All of the above

Correct Answer

verifed

verified

Explain what can be done during the rough-in phase to make switch installation easier in the finish phase of the wiring process.

Correct Answer

verifed

verified

Mark and group the c...

View Answer

The proper NEMA designation for a 15 amp, 125 volt receptacle is __________.


A) 5-15R
B) 5-15P
C) 5-20R
D) 6-15R

E) A) and C)
F) C) and D)

Correct Answer

verifed

verified

A

A multiple receptacle has more than __________ contact device(s) on the same yoke.


A) 1
B) 2
C) 3
D) 4

E) C) and D)
F) A) and B)

Correct Answer

verifed

verified

A __________ receptacle is one that has internal shutters that are closed behind the receptacle slots when there is no attachment plug inserted. The shutters open when a plug is inserted allowing the plug (and cord) to become energized.


A) duplex
B) single
C) tamper resistant
D) GFCI

E) C) and D)
F) B) and C)

Correct Answer

verifed

verified

List the 5 types of AFCI devices currently recognized by Underwriters Laboratories (UL).

Correct Answer

verifed

verified

1. Branch/Feeder AFC...

View Answer

GFCI receptacles should be tested at least once per __________.


A) day
B) week
C) month
D) year

E) B) and D)
F) All of the above

Correct Answer

verifed

verified

C

Explain why it is recommended to install receptacles with the grounding slot up.

Correct Answer

verifed

verified

To lessen the chance...